• Search
  • Tracker
  • Features
  • FAQ
  • Insights
  • About Us
  • Support Us
  1. Search
  2. Results
  3. Goods Information
Good

Last Updated: June 13, 2026

  1. Search
  2. Results
  3. Goods Information

Last Updated: June 13, 2026

Good

Dimensional inspection machines, instruments, or systems, as follows: a. Computer controlled or numerically controlled coordinate measuring machines (CMM) having both of the following characteristics: 1. Two or more axes; and 2. A maximum permissible error of length measurement (E0, MPE) along any axis (one dimensional), identified as E0x, E0y, or E0z, equal to or less (better) than (1.25 + L/1000) μm (where L is the measured length in mm) at any point within the operating range of the machine (i.e., within the length of the axis), tested according to ISO 10360-2(2009). b. Linear displacement measuring instruments, as follows: 1. Non-contact type measuring systems with a "resolution" equal to or better (less) than 0.2 μm within a measuring range up to 0.2 mm; 2. Linear variable differential transformer (LVDT) systems having both of the following characteristics: a. "Linearity" equal to or better (less) than 0.1% within a measuring range up to 5 mm; and b. Drift equal to or better (less) than 0.1% per day at a standard ambient test room temperature ± 1 K; 3. Measuring systems having both of the following characteristics: a. Contain a laser; and b. Maintain for at least 12 hours, over a temperature range of ± 1 K around a standard temperature and a standard pressure: 1. A "resolution" over their full scale of 0.1 μm or better; and 2. With a "measurement uncertainty" equal to or better (less) than (0.2 + L/2000) μm (L is the measured length in millimeters);

Category

LIST OF NUCLEAR-RELATED DUAL-USE EQUIPMENT, MATERIALS, SOFTWARE, AND RELATED TECHNOLOGY

Subcategory

1.B. Test and Production Equipment

Prohibited Supply To

IR

Authority

GB

Document

INFCIRC/254/Rev.8/Part 2

Note

Note: Item 1.B.3.b.3. does not control measuring interferometer systems, without closed or open loop feedback, containing a laser to measure slide movement errors of machine tools, dimensional inspection machines, or similar equipment. Technical Note: In Item 1.B.3.b. ‘linear displacement’ means the change of distance between the measuring probe and the measured object. c. Angular displacement measuring instruments having an "angular position deviation" equal to or better (less) than 0.00025°; Note: Item 1.B.3.c. does not control optical instruments, such as autocollimators, using collimated light (e.g., laser light) to detect angular displacement of a mirror. d. Systems for simultaneous linear-angular inspection of hemishells, having both of the following characteristics: 1. "Measurement uncertainty" along any linear axis equal to or better (less) than 3.5 μm per 5 mm; and 2. "Angular position deviation" equal to or less than 0.02°. Notes: 1. Item 1.B.3. includes machine tools that can be used as measuring machines if they meet or exceed the criteria specified for the measuring machine function. 2. Machines described in Item 1.B.3. are controlled if they exceed the threshold specified anywhere within their operating range. Technical Note: All parameters of measurement values in this item represent plus/minus, i.e., not total band.

Program information

Program information

Have feedback, suggestions or need help navigating sanctions? Let's talk.

Let's discuss how Sanctions Finder can support you or your business or organization.

Product

  • Search
  • Sanctions Tracker
  • Platform Features

Company

  • About Sanctions Finder
  • Insights

Support

  • FAQ
  • Contact Us

Legal

  • Terms of Use
  • Privacy Policy
XLinkedInContact Us

© 2026 Sanctions Finder