Last Updated: March 5, 2026

‘Pressure transducers’, other than those defined in 2B230, capable of measuring absolute pressures at any point in the range 0 to 200 kPa and having both of the following characteristics: a. Pressure sensing elements made of or protected by ‘Materials resistant to corrosion by uranium hexafluoride (UF 6 )’; and b. Having either of the following characteristics: 1. A full scale of less than 200 kPa and an ‘accuracy’ of better than ± 1 % of full scale; or 2. A full scale of 200 kPa or greater and an ‘accuracy’ of better than 2 kPa. Technical note : For the purposes of 2B230 ‘accuracy’ includes non-linearity, hysteresis and repeatability at ambient temperature.

Code

2B230

EU Code

II.A2.007

Categories

Subcategory

2B - Test, Inspection and Production Equipment

Prohibited Supply To

Iran

Authority

EU

Document

EU Regulation No 267/2012

Note

Program information